PROJECT-GRADE OUTDOOR CABINET

Outdoor Network Cabinet for Power, Network & Control Equipment

Custom outdoor network cabinets for telecom, power, control and AV equipment. Cabinet size, internal layout, cable entry, cooling and maintenance access can be configured around your equipment list, wiring diagram and installation method.

Send us your equipment list or cabinet drawing for project review before quotation.

IP65 Weather Protection Custom Internal Layout Thermal & Humidity Control
Outdoor Network Cabinet Exterior and Internal Layout

Custom Internal Layout

Matched to your equipment list & wiring diagram

Custom Equipment Layout for Outdoor Network Cabinets

Every project uses a different combination of network, power and control equipment. We plan rack space, mounting plates, cable routing, power distribution, cooling clearance and maintenance access around your equipment list and wiring diagram.

Network & Signal

Plan rack space and cable routing for switches, routers, fiber converters and signal devices based on equipment dimensions and connection requirements.

Power & Control

Arrange industrial power supplies, control modules, circuit breakers, AC contactors and terminal blocks with clear service access.

Power Distribution

Plan sockets, terminal blocks and strong-current wiring so power components do not block equipment installation or maintenance.

Sensors & Monitoring

Placement for temperature control boards and sensor modules to accurately reflect internal cabinet conditions.

Internal Equipment Layout Planning

Outdoor Network Cabinets Built for Real Site Conditions

Outdoor network cabinets face rain, heat, humidity, dust, corrosion and wiring constraints. We configure sealing, cooling, filtration, cable entry and materials around your equipment and installation environment.

Rain and Water Ingress Protection

Rain & Water Ingress

Outdoor installations may be exposed to rain through doors, joints and cable openings.

Sealed doors, protected cable entry and weather-resistant enclosure structures help reduce water intrusion.

IP65 Protection  Sealed Door  Cable Entry
Equipment Heat Buildup Management

Heat Buildup

Switches, power supplies and controllers can generate continuous heat inside enclosed cabinets.

Ventilation, fan cooling or active cooling can be selected according to equipment heat load and ambient temperature.

Fan Cooling  Ventilation Thermal Control
Humidity and Condensation Control

Humidity & Condensation

High humidity and temperature changes may cause condensation around electrical components.

Heating, dehumidification and humidity sensing can be configured according to site conditions.

Heating Dehumidification Humidity Sensor
Dust and Insects Protection

Dust & Insects

Roadside, park and industrial sites may expose cabinet equipment to dust and insects.

Filtered airflow and sealed openings help reduce contamination while keeping filters accessible for maintenance.

F6 Filter Sealed Air Path  Easy Maintenance
Cable Entry and Wiring

Cable Entry & Wiring

Power, network and signal cables often require different routing paths inside the cabinet.

Cable glands, terminal areas and separated wiring routes can be planned according to the wiring diagram.

Cable Glands Cable Routing  Separated Wiring
Corrosion and Outdoor Exposure

Corrosion & Outdoor Exposure

Coastal, humid and long-term outdoor installations may require stronger corrosion resistance.

Galvanized steel, 201/304 stainless steel and outdoor powder coating can be selected according to the site environment.

Galvanized Steel 304 Stainless Steel Powder Coating
Project Configuration Review

Need Help Configuring Your Outdoor Network Cabinet?

Send your equipment list, wiring diagram or site photos. We can review cabinet size, internal layout, cooling, cable entry, material and installation method.

Equipment List
Wiring Diagram
Site Photos
Send Equipment List
Prefer WhatsApp? Send project details

Outdoor Network Cabinet Structure Breakdown

Each cabinet is configured around your equipment, wiring diagram and site conditions. Material, mounting structure, sealing, cable entry, cooling and sensor options can be reviewed before production.

Outdoor Network Cabinet Structure Breakdown
1

Cabinet Body Materials

201 stainless steel, 304 stainless steel or galvanized steel can be selected according to corrosion level, installation environment and project requirements.

2

Door Sealing Structure

Door gaskets and overlapping edges help reduce rain, dust and moisture entry during outdoor installation.

3

Mounting Rails & Internal Plate

Rack rails, shelves and mounting plates can be arranged around switches, power supplies, controllers and other equipment.

4

Maintenance Access & Cable Entry

Door direction and bottom or side cable entry can be planned according to wiring route and service access.

5

Ventilation & Cooling

Fan positions, ventilation openings or active cooling can be configured according to equipment heat load and ambient conditions.

6

Electrical & Sensor Options

Sockets, terminal blocks, temperature control boards, temperature/humidity sensors, smoke alarms and water-leak alarms can be added according to project needs.

Power Distribution & Cable Routing for Outdoor Network Cabinets

A clear internal power layout helps simplify installation and maintenance. We review your wiring diagram to plan terminal blocks, sockets, power modules, cable entry and separated power and signal routes before production.

  • Socket & Terminal Layout
    Multifunctional sockets and terminal blocks can be positioned around the equipment layout.
  • Power Component Planning
    AC contactors, circuit breakers and power-supply mounting space can be reserved according to project requirements.
  • Separated Cable Routing
    Power and signal cable routes can be separated according to the wiring diagram and available cabinet space.
  • Cable Entry & Service Access
    Cable entry and service clearance can be planned to support field wiring and maintenance.
Send Wiring Diagram
Cabinet Wiring Design Terminal Layout Details

Typical Internal Power Layout

Final layout is reviewed according to your equipment list and wiring diagram.

Thermal & Humidity Control for Outdoor Network Cabinets

Weather sealing reduces natural air exchange, while network, power and control equipment continue to generate heat. Cooling, heating and humidity control can be configured according to equipment heat load, ambient temperature and site conditions.

Automatic Temperature & Humidity Control

Temperature Control Board System Diagram
Temperature Sensor Humidity Sensor Fan Output Heating Output Smoke Alarm Water-Leak Alarm

A temperature control board can work with temperature and humidity sensors to manage fan cooling, heating and dehumidification according to preset operating conditions.

Fan Cooling Logic

Example configuration: if the cabinet temperature rises 2°C or more above the preset value (for example, 35°C), fan cooling starts automatically. When the temperature falls 2°C or more below the preset value, the fan stops.

Example Setpoint: 35°C

Heating & Dehumidification Logic

Example configuration: when cabinet temperature is ≤5°C and humidity is ≥85%, heating starts automatically. Heating stops when temperature reaches 10°C and humidity falls to ≤75%.

Start: ≤5°C / ≥85% RH
Stop: 10°C / ≤75% RH

Sensor & Alarm Options

Temperature and humidity sensing can be combined with smoke and water-leak alarms according to project requirements.

Temp Sensor Humidity Sensor Smoke Alarm Water-Leak Alarm
Discuss Thermal Control

Installation Options for Outdoor Network Cabinets

Mounting method affects cabinet support structure, cable entry, service access and internal layout. Wall, pole, floor or project-frame mounting can be selected according to site space, equipment load and project drawings.

Wall-mounted outdoor network cabinet

Wall-Mounted

Best For: Building exteriors, equipment rooms, commercial facilities and sites with limited ground space.

Key Design Checks: Rear mounting points, wall clearance, door opening direction and cable entry should be reviewed before production.
Benefit: Saves ground space while keeping equipment accessible for maintenance.

Benefits: Saves ground space, keeps equipment away from ground moisture.

Pole-mounted outdoor network cabinet

Pole-Mounted

Best For: Smart city, surveillance, roadside communication and distributed network nodes.

Key Design Checks: Pole diameter, mounting bracket, cabinet size, cable routing and site exposure should be reviewed according to project requirements.
Benefit: Suitable for distributed equipment points where floor installation is not practical.

Benefits: Ideal for street-level deployment and distributed network nodes.

Floor-standing outdoor network cabinet

Floor-Standing

Best For: Larger network, power and control cabinets used in parks, plazas, industrial sites and outdoor AV projects.

Key Design Checks: Base dimensions, bottom cable entry, service clearance and site drainage should be considered before installation.
Benefit: Provides more internal space for equipment, power distribution and cable management.

Benefits: Supports larger equipment loads and extensive power distribution.

Project-frame mounted cabinet

Project-Frame Mounted

Best For: Custom equipment frames, AV systems, industrial structures and project-specific support assemblies.

Key Design Checks: Cabinet footprint, mounting holes, cable direction and maintenance clearance should match the project drawing.
Benefit: Allows the cabinet to integrate with custom project structures and equipment layouts.

Benefits: Seamless integration with complex outdoor projection or AV systems.

Custom Outdoor Network Cabinets for Project & OEM Buyers

Every project has different equipment, wiring and installation requirements. Customization can start from your equipment list, cabinet drawing, wiring diagram, installation method and site photos.

For repeated project deployments or OEM orders, dimensions, internal layout, mounting points and electrical configuration can be reviewed before batch production.

Equipment List Cabinet Drawing Wiring Diagram Site Photos

Step 01: Requirement Review

Review equipment list, cabinet dimensions, site conditions, installation method and project quantity.

Step 02: Structure & Layout Design

Confirm cabinet size, mounting holes, internal rails or mounting plates, cable entry, door direction and service access.

Step 03: Electrical & Thermal Integration

Plan power distribution, control board position, sensors, cable routing, ventilation or cooling according to the wiring diagram and equipment heat load.

Step 04: Sample & Batch Production

For OEM or repeated deployments, a sample or first-unit review can be used to confirm dimensions, layout and configuration before batch production.

No cabinet drawing yet? Send your equipment list, wiring diagram and site photos instead.

Outdoor Network Cabinet Project Installation
Project-Based Customization

Cabinet structure and mounting configuration reviewed around equipment, wiring and site requirements.

Outdoor Network Cabinet Applications

Designed for outdoor network, power and control equipment used in smart city, telecom, AV, advertising and industrial projects.

Outdoor projector system cabinet

Smart City & Surveillance

Used for roadside and distributed network nodes housing switches, surveillance devices and IoT equipment.

Cable Entry · Compact Layout · Environmental Protection
Scenic night-tour control cabinet

Telecom & Communication

For outdoor communication equipment, fiber devices, switches and signal transmission modules.

Terminal Layout · Cable Routing · Thermal Management
Smart city equipment cabinet

Scenic Night-Tour & Lighting Control

Supports lighting controllers, signal devices, switches and power distribution equipment.

Humidity Control · Wiring · Sensor Options
Outdoor advertising control cabinet

Outdoor AV & Projection Control

Used alongside outdoor projection systems for media players, network switches, controllers and power equipment.

AV Signal · Power Distribution · Cooling
Telecom equipment cabinet

Outdoor Advertising & LED Display

For LED controllers, industrial power supplies, network devices and signal equipment.

Heat Dissipation · Power · Service Access
Industrial outdoor equipment cabinet

Industrial & Utility Sites

For factories, utility projects and harsh outdoor sites requiring protected network, power and control equipment.

Material Selection · Corrosion Resistance · Thermal Control

Indoor Network Rack vs Outdoor Network Cabinet

Compare environmental protection, cooling, cable entry, mounting and customization before selecting a cabinet for your project.

Design Factor Indoor Network Rack Outdoor Network Cabinet
Installation Environment Controlled indoor server rooms and equipment rooms. Outdoor sites exposed to rain, dust, humidity, temperature changes and other environmental conditions.
Weather & Dust Protection Typically designed for controlled indoor environments; outdoor ingress protection is not the primary requirement. Sealed doors, protected cable entry and weather-resistant structure; IP65 configurations can be discussed according to project requirements.
Cable Entry Standard top or bottom cable openings. Cable glands and entry direction can be planned according to wiring route and installation method.
Thermal & Humidity Control Usually relies on room air conditioning and indoor ventilation. Fan cooling, heating, dehumidification or active cooling can be configured according to equipment heat load and site conditions.
Power & Wiring Layout Standard rack PDUs and conventional indoor cable management. Sockets, terminal blocks, power modules and cable routes can be arranged according to equipment list and wiring diagram.
Mounting Method Primarily floor-standing rack installation. Wall-mounted, pole-mounted, floor-standing or custom project-frame installation.
Materials & Corrosion Materials selected mainly for controlled indoor environments. Galvanized steel, 201/304 stainless steel and outdoor surface treatments can be selected according to site conditions.
Maintenance Access Front and rear access is usually available inside equipment rooms. Door direction, service clearance, filter access and cable routing can be planned around the installation site.
Project Customization Commonly based on standard 19-inch rack dimensions and rack units. Dimensions, mounting rails, internal plates, cooling, cable entry and service access can be customized around project equipment.

Outdoor Network Cabinet Specification Guide

Final specifications for your custom outdoor network cabinet are confirmed according to your equipment list, cabinet drawing, wiring diagram and site conditions.

Structure

Product Name
Outdoor Network Cabinet
Cabinet Size
Customized according to equipment dimensions, internal layout and installation requirements.
Material Options
201 Stainless Steel / 304 Stainless Steel / Galvanized Steel
Surface Treatment
Outdoor powder coating or project-specific surface finish.
Internal Layout
Customized around the equipment list, mounting rails, internal mounting plates and required service space.

Protection & Environment

Protection
IP65 configuration available according to project requirements.
Cable Entry
Bottom or side cable entry can be planned according to the wiring diagram and installation method.
Cooling Options
Natural Ventilation / Fan Cooling / Active Cooling / Temperature Control.
Cooling method should be discussed according to equipment heat load, ambient temperature and cabinet structure.
Sensor Options
Temperature / Humidity / Smoke / Water-Leak (Available according to project requirements).

Electrical

Power Configuration
Multifunctional sockets, terminal blocks, circuit breakers and AC contactors can be configured according to project requirements.

Project Configuration

Installation Method
Wall-Mounted / Pole-Mounted / Floor-Standing / Project-Frame Mounted
Customization Input
Equipment List / Cabinet Drawing / Wiring Diagram / Site Photos

Need a Cabinet Specification for Your Project?

Send your equipment list, cabinet drawing or wiring diagram. We can review cabinet size, internal layout, material, cable entry, cooling and electrical configuration before quotation.

Final dimensions, internal layout and electrical configuration are confirmed before production.

Manufacturing & Project Capability

Buyers can review product photos, factory videos, and project case materials before sending cabinet drawings or wiring diagrams. Certification documents are available on request.

Sheet metal processing and cabinet assembly factory video
Engineering project case photo
Certificates available on request
Industrial power supply board and temp control matching

Project Inquiry Process

Clear steps to ensure the final cabinet matches your exact field requirements.

1

Send Equipment List

Provide dimensions for all network, power, and control devices.

2

Share Cabinet Drawing

Send drafts if available, or we can design based on step 1.

3

Share Wiring Diagram

Crucial for planning terminal layouts and separating currents.

4

Confirm Installation

Wall, pole, floor, or project-frame mounting method.

5

Review Size & Layout

Confirm internal mounting plate and maintenance clearance.

6

Entry & Sockets

Confirm cable entry direction and multifunctional socket position.

7

Cooling & Sensors

Discuss temperature control board and alarm options.

8

Quote & Order

Request a quote, approve sample, and proceed to mass production.

Frequently Asked Questions

Technical details for project engineers and procurement teams.

What is an Outdoor Network Cabinet?
An outdoor network cabinet is a robust enclosure used in outdoor engineering projects to install and protect power modules, network equipment, control devices, and communication modules from weather, dust, and vandalism.
What is the difference between an outdoor network cabinet and an indoor network rack?
Indoor racks are open frames designed for climate-controlled server rooms. Outdoor network cabinets feature waterproof sealing, specialized cable entry, active temperature control, and rugged materials to survive harsh environments.
What equipment can be installed inside the cabinet?
You can install network switches, routers, industrial power supply boards, control modules, signal devices, multifunctional sockets, AC contactors, and temperature control boards, depending on your internal layout design.
Can the cabinet be customized according to equipment layout?
Yes. We highly recommend sending your equipment list and wiring diagram. We review cabinet dimensions, internal mounting plates, and maintenance clearances to ensure everything fits perfectly and is easy to service on-site.
What materials are available?
The cabinet body can be manufactured from 201 stainless steel, 304 stainless steel, or galvanized plate, depending on the corrosion level of your outdoor installation environment.
Can cable entry and socket layout be customized?
Absolutely. Cable entry direction must match your underground wiring or bridge routing. Socket positions and terminal layouts are arranged so they do not block equipment maintenance.
What cooling options are available?
Ventilation, fan cooling, or active temperature control matching can be discussed according to the equipment heat load, cabinet size, and site temperature.
Can a temperature control board be installed inside?
Yes, a temperature control board can be matched with internal sensors to manage cooling fans and heating modules automatically based on preset thresholds.
Is the cabinet suitable for outdoor projector system projects?
Yes. Outdoor projector systems often require network, power, and control devices housed in one secure location. We design the cabinet to integrate seamlessly with the overall AV project layout.
What installation methods are available?
The cabinet can be configured for wall-mounted, pole-mounted, floor-standing, or project-frame installation. The structure and back plate are adapted accordingly.
What information is needed for a quote?
Please provide your equipment list, expected cabinet size, material requirement, installation method, expected project quantity, and any specific cooling or sensor requirements.
Can I send my cabinet drawing and wiring diagram?
Yes, we encourage it. Sending your cabinet drawing and wiring diagram allows our engineering team to review the layout, cable entry, and maintenance access before mass production.
ShiRui Logo

Send Your Cabinet Requirements

To provide an accurate quote and layout design, please prepare the following details for your outdoor engineering project:

  • Equipment list & dimensions
  • Cabinet drawing & wiring diagram (if any)
  • Installation method & site photos
  • Material & cooling requirements
  • Expected project quantity

info@projectorshellbox.com

+8613632871992

Room 103,BuildingB,Pingtaichang Science and Technology Park, No. 15. Xiongyu Road, Tangxiayong Community, Yanluo Street, Baoan District, Shenzhen